Высокие технологии Undo the screws and clips (arrowed) and separate the two halves of the housing
просмотров - 183

Undo the two bolts (arrowed) to separate the blower motor housing

Unclip the amplifier from above the cooling unit (arrowed)

Refitting

Push the radiator rearwards, and slide the condenser from position

A Condenser upper support bolt

(arrowed)...

remove the two bolts and separate the blower motor housing from the evaporator housing

(see illustration).

7 Remove the screws and clips and separate the top and bottom halves of the case and pull out the evaporator (see illustration).

8 Pull the thermistor sensor probe from the evaporator matrix, and unbolt the expansion valve and the two short refrigerant pipes (see illustrations).Discard the O-ring seals, newones must be fitted.

9 The evaporator matrix can be cleaned with a 'fin comb' and blown off with compressed air.

Warning: Be sure to wear
eye protection when using
compressed air.    

10 Refitting is the reverse of the removal process. Be sure to use new O-rings, and new gaskets on the expansion valve.

Cooling, heating and air conditioning systems 3•13