Open Library - открытая библиотека учебной информации

Открытая библиотека для школьников и студентов. Лекции, конспекты и учебные материалы по всем научным направлениям.

Категории

Строительство Relay Circuit Inspection (with the battery disconnected)
просмотров - 250

ELECTRICAL SYSTEM 16-63 Junction Box

Fuse Circuit Inspection

Junction Box

ELECTRICAL SYSTEM

The junction box [A] has fuses [B], relays, and diodes. The relays and diodes can not be removed.

Junction Box Fuse Circuit Inspection

• Remove the left side cover (see Side Cover Removal in the Frame chapter).

Remove the junction box.

Pull off the connectors from the junction box.

• Make sure all connector terminals are clean and tight, and none of them have been bent.

• Clean the dirty terminals, and straighten slightly-bent ter­minals.

• Check conductivity of the numbered terminals with the hand tester.

• If the tester does not read as specified, replace the junc­tion box.

Special Tool - Hand Tester: 57001-1394

Tester Connection Tester Reading (Ω) Tester Connection Tester Reading (Ω)
1 - 1A 1A - 8 ОО
1-2 2-8 ОО
3A - 4 3A - 8 ОО
6-5 6-2 ОО
6 - 10 6 - 3A ОО
6-7 17 - 3A ОО
6 - 17    

Starter Circuit/Headlight Relay Inspection

• Remove the left side cover (see Side Lover Removal in the Frame chapter).

• Remove the junction box.

• Check conductivity of the following numbered terminals by connecting the hand tester and one 12V battery to the junction box as shown.

• If the tester does not read as specified, replace the junc­tion box.

Special Tool - Hand Tester: 57001-1394

  Te s t e r Connection Tester Reading (Ω)   Test e r Connection Tester Reading (Ω)
Headlight Relay 7-8 ОО Starter Circuit Relay 9 -11 ОО
7-13 ОО 12 -13 ОО
(+) (-) 13-9 Not ∞ * (+) (-) 13-11 (+) (-) 12 -11 ∞ Not ∞ *

(*): The actual reading varies with the hand tester used. (+): Apply tester positive lead. (–): Apply tester negative lead.